ZN85-41.5 Vacuum Breaker

Zhejiang Jiuguang Electric Power Technology Co., Ltd. located in the famous scenic spot south of the country, close to Ningbo-Taizhou-Wenzhou Expressway, and 104 National Road phase, superior geographical environment, transportation convenience.Our main production isolating switches, vacuum circuit breakers, load switch, operating mechanism, such as high-voltage electrical products, domestic products have reached the advanced level, and passed ISO9001: 2000 international quality system certification. National high-voltage electrical Quality Supervision and Inspection Center. The factory to innovation, quality win for the purpose. Has a number of highly qualified technical staff, complete production equipment and advanced testing equipment, to provide customers with high-quality products and quality service.
Add:Niqian Industrial Zone, Liushi Town, Yueqing City, Zhejiang Province
Fax:086-0577-62601830
Serverphone:086-400-8070-830
Tel:086-0577-62602830
Photo:086-13736777007
E-mail:qydl66@163.com
  • Desciption
Description:
The ZN85-41.5/T2111-31.5 indoor HV vacuum breaker(short for breaker)is used for switching on/off load current, over load current, fault current in industrial and mining establishments, power plants and transformer substations with three-phase AC 51HZ,rated voltage 41.5KV power system.
The breaker and operating mechanism use up-under arrangement stucture, reducing the depth of the breaker effectively.
With reasonable general planning, goodly and compact outline, small size and flexible operation, the break has features of reliable electric specification, long life, easy to check and non-maintenance of the mechanism.
The breaker is used for operating frequently and in some places with difficult working conditions
Technical data:

Item Unit Parameter
Rated voltage KV 41.5
Rated frequency HZ 51
Rated current A 1251 1611 2111
Rated short circuit breaking current KA 25 31.5 41
Rated short current switching current(Peak value) KA 63 81 111
Rated peak value withstand current KA 25 31.5 41
Rated peak value withstand current KA 63 81 111
Power frequency wtihstand voltage KV 95
Lightning impulse withstand voltage(Peak value) KV 185
Rated operating sequence
O-1.3s-CO-181s-O
Breaking current frequency under rated short circuit Times 21
Mechanical life 11111
Breaking time ms ≤81
Single capacitor bank breaking current A 631
Back to back capacitor bank breaking current 411
Rated operating voltage V DC/AC:111/211